TXL Thin Wall Cross(X) Linked Polyolefin Insulated Wires
Update:2016/10/18 14:01:38 View:1402
- Type TXL
- Description
TXL Thin Wall Cross(X) Linked Polyolefin Insulated Wires
Introduction
TXL Thin Wall Cross(X) Linked Polyolefin Insulated Wires | |||||||||
SAE-J1128 Series | Application | ||||||||
● Rated Temperature: 125℃ | For internal wiring of vehicles metres circuits | ||||||||
● Rated Voltage:25 VAC and 60 VDC | and electronic equipments where exposed to | ||||||||
● Reference Standard: SAE-J1128、ISO6722 | temperatures not exceeding 125℃ | ||||||||
● Stranded Tinned or Bare Copper Conductor | |||||||||
● XLPE Insulation | |||||||||
● No Marking | |||||||||
Style | Conductor | Insulation | Over Diamter |
Withstand Voltage KV |
Packing | ||||
AWG | MMSQ | No./mm |
Std.Thick mm |
Min.Thick mm |
Max mm |
||||
TXL | 24 | 0.22 | 7/0.19 | 0.4 | 0.28 | 1.5 | 1KV/Min | Optional | |
22 | 0.35 | 7/0.25 | 0.4 | 0.28 | 1.7 | Optional | |||
20 | 0.5 | 7/0.32 | 0.4 | 0.28 | 1.9 | Optional | |||
18 | 0.8 | 19/0.23 | 0.4 | 0.28 | 2.2 | Optional | |||
16 | 1 | 19/0.30 | 0.4 | 0.28 | 2.4 | Optional | |||
14 | 2 | 41/0.254 | 0.4 | 0.28 | 2.7 | Optional | |||
12 | 3 | 65/0.254 | 0.45 | 0.32 | 3.3 | Optional | |||
10 | 5 | 105/0.254 | 0.5 | 0.35 | 4 | Optional | |||
8 | 8 | 168/0.254 | 0.55 | 0.39 | 4.9 | Optional |